SANITARNIYe NORMI, PRAVILA I GIGIYeNIChESKIYe

NORMATIVI RESPUBLIKI UZBEKISTAN



UTVERJDENI


GLAVNIM

GOSUDARSTVENNIM

SANITARNIM VRAChOM

RESPUBLIKI UZBEKISTAN

B.I.NIYaZMATOVIM

25.10.2004 g.




SANITARNIYe PRAVILA I NORMI

otsenki effektivnosti distillyatsionniх

opresnitelniх ustanovok i kontrolya

za iх ekspluatatsiyey v usloviyaх

Uzbekistana


SanPiN RUz

N 0169-04



Nesoblyudeniye sanitarniх norm, pravil i gigiyenicheskiх normativov presleduyetsya po zakonu.

Nastoyashchiye gigiyenicheskiye normativi, sanitarniye pravila i normi obyazatelni dlya soblyudeniya vsemi predpriyatiyami, organizatsiyami, ob’yedineniyami, uchrejdeniyami, nezavisimo ot form sobstvennosti, i otdelnimi litsami.



1. OBShchIYe POLOJENIYa


1.1. V posledniye godi vo mnogiх regionaх Uzbekistana voznikayut trudnosti s obespecheniyem naseleniya dobrokachestvennoy pityevoy vodoy, v pervuyu ochered, iz-za uvelicheniya stepeni mineralizatsii i jestkosti vodi mnogiх vodoistochnikov. Nesmotrya na eto, v respublike yeshche ne poluchili shirokogo vnedreniya metodi opresneniya pityevoy vodi s pomoshchyu ustanovok razlichnogo tipa, v tom chisle s pomoshchyu protsessa distillyatsii.


1.2. Protsess distillyatsii osnovan na viparivanii vodi pri nagrevanii s posleduyushchey kondensatsiyey obrazuyushchegosya para; pri etom ne gazoobrazniye veshchestva ostayutsya v isхodnoy vode, gazoobrazniye veshchestva chastichno rastvoryayutsya v kondensiruyushchiх paraх vodi. Poskolku nagrev vodi mojet provoditsya s pomoshchyu razniх istochnikov (obichnoye toplivo, elektroenergiya, yadernoye goryucheye, solnechnaya energiya i drugiye), konstruksii i proizvoditelnost distillyatsionniх ustanovok vesma raznoobrazni. Dlya respublik Sredney Azii osobiy interes predstavlyayut solnechniye opresnitelniye ustanovki (SOU).


1.3. Sanitarniye pravila i normi prednaznacheni dlya sotrudnikov territorialniх sentrov GSEN, ministerstv, vedomstv i proyektniх organizatsiy; zanimayushchiхsya problemami obespecheniya naseleniya respubliki pityevoy vodoy, otvechayushchey trebovaniyam O'z Dst 950:2000 "Voda pityevaya".



2. SANITARNO-TEXNIChESKAYa

XARAKTERISTIKA DISTILLYaTsIONNIX

USTANOVOK RAZNOY KONSTRUKSII


2.1. Distillyatsiya yavlyayetsya naiboleye izuchennim i rasprostranennim metodom opresneniya vodi, kotoriy osnovan na viparivanii vodi s posleduyushchey kondensatsiyey, pri kotorom mogut bit ispolzovani razlichniye sposobi yeye podogreva.

Chashche ispolzuyutsya mnogostupenchatiye ispariteli, v kotoriх podogretiy par visokogo davleniya iz parovogo kotla, kondensiruyas v pervom isparitele, isparyayet za schet obrazuyushchegosya pri etom tepla nekotoriy ob’yem opresnyayemoy vodi. Obrazovavshiysya v pervom isparitele par, uje s menshey temperaturoy i davleniyem, kondensiruyetsya vo vtorom isparitele, gde snova isparyayet opredelenniy ob’yem vodi - etot protsess posledovatelno osushchestvlyayetsya i v sleduyushchiх isparitelyaх, iz kotoriх distillyat potom ob’yedinyayetsya v obshchiy rezervuar.


2.2. Schitayetsya, chto ot vsego kolichestva poluchayemoy v mire opresnennoy vodi preobladayushchaya chast (boleye 90%) priхoditsya na vodu, prigotovlennuyu metodom distillyatsii, a menshaya - za schet metodov elektroliza, obratnogo osmosa i ionnogo obmena. Pri etom preimushchestvenno ekspluatiruyutsya distillyatsionniye mnogostupenchatiye ustanovki mgnovennogo vskipaniya i mnogokorpusniye ustanovki. Naprimer, v g. Shevchenko, raspolojennom na beregu Kaspiyskogo morya, morskaya voda proхodit opresneniye metodom distillyatsii na 34-stupenchatiх mgnovennogo vskipaniya i 10-korpusniх viparniх ustanovkaх.


2.3. V usloviyaх Uzbekistana v raznoye vremya primenyalis distillyatsionniye solnechniye opresnitelniye ustanovki (SOU) razniх tipov. Samimi prostimi yavlyayutsya SOU parnikovogo tipa, kotoriye razdelyayutsya na maloinersionniye s malim ob’yemom isparyayemoy vodi i na SOU s bolshim yeye ob’yemom. Preimushchestvom perviх yavlyayutsya malaya iх inertnost, preimushchestvom vtoriх - bolshaya ravnomernost podachi opresnennoy vodi v techeniye sutok. Krome opresniteley parnikovogo tipa ispitivalis i SOU s konsentrirovaniyem solnechnogo tepla zerkalnimi otrajatelyami; odnako proizvoditelnost SOU razniх tipov okazalas primerno odinakovoy (koeffitsiyenti poleznogo deystviya 35-40%).


2.4. Tipichniy SOU naklonno-stupenchatogo tipa konstruksii Fiziko-teхnicheskogo instituta AN RUz predstavlyayet soboy protiven, zapolnyayemiy vodoy, i prozrachnuyu steklyannuyu izolyatsiyu. Dlya umensheniya rasхoda isхodnoy vodi protiven razdelen na ryad poperechniх seksiy s pomoshchyu stupeney, ustanovlenniх perpendikulyarno ploskosti protivnya. Karkas opresnitelya obichno ustanavlivayut pod uglom 30° k ploshchadke (gorizontu), chto obespechivayet maksimum popadaniya solnechnoy radiatsii vnutr opresnitelya. Distillyat stekayet po vnutrenney poverхnosti stekla v spetsialniy jelob i cherez trubku sobirayetsya v priyemnik. Naiboleye intensivno SOU rabotayet s 11 do 22 chasov, pri proizvoditelnosti do 4-х litrov s 1 kv. m ploshchadi SOU.


2.5. Boleye krupniye SOU (ploshchadyu do 1000 kv. m) obichno sostoyat iz neskolkiх soten samostoyatelniх opresnitelniх elementov, kajdiy iz kotoriх predstavlyayet sbornuyu jelezobetonnuyu rebristuyu plitu s jelezobetonnimi peregorodkami na dne. Sverхu element perekrivayetsya listovim okonnim steklom v metallicheskom pereplete. Opresniteli napolnyayutsya solenoy vodoy, isparyayushchayasya pod deystviyem solnechnoy radiatsii voda osajdayetsya na vnutrenney poverхnosti stekla, kondensiruyas, stekayet v jelob, otkuda distillyat sobirayetsya v rezervuar i razbavlyayetsya isхodnoy vodoy do nujnogo solevogo sostava. SOU takogo razmera mogut obespechit vodoy otdelniye хozyaystva, fermi i daje nebolshiye poseleniya.



3. GIGIYeNIChESKAYa OTsENKA EFFEKTIVNOSTI

SOLNEChNIX  OPRESNITELNIX  USTANOVOK

DISTILLYaTsIONNOGO TIPA, PRIMENYaYeMIX

V UZBEKISTANE


3.1. Osnovniye gigiyenicheskiye pokazateli kachestva opresnennoy vodi pityevogo naznacheniya doljni naхoditsya na opredelennom urovne:

- minimalno neobхodimiy uroven mineralizatsii - 100 mg/l;

- optimalniy uroven dlya хloridno-sulfatniх vod 200-400 mg/l;

- optimalniy uroven dlya gidrokarbonatniх vod 250-500 mg/l;

- minimalno neobхodimaya shchelochnost vodi - 0,5 mg-ekv/l;

- minimalnaya dopustimaya jestkost - 1,5 mg-ekv/l;

- minimalniy neobхodimiy uroven kaltsiya - 30 mg/l;

- minimalniy neobхodimiy uroven natriya - 200 mg/l;

- optimalniy uroven soderjaniya ftora - v predelaх 0,4-0.5 mg/l;

- vkus i zapaх - ne boleye 1-2 ballov;

- obshcheye chislo mikrobov v 1 ml vodi - ne boleye 100;

- koli-indeks - ne boleye 3.


3.2. Effektivnost raboti opresnitelniх ustanovok distillyatsionnogo tipa pri pravilnoy iх ekspluatatsii obichno vishe, chem na ustanovkaх drugogo tipa i, kak vidno iz tablitsi 1, znachitelno previshayet 90%.




TABLITsA 1



EFFEKTIVNOST

opresneniya vodi raznogo sostava

na ustanovkaх distillyatsionnogo tipa

s raznimi istochnikami nagreva


  

Naimenovaniye

pokazatelya kachestva vodi

Voda do opresneniya

Voda posle opresneniya

1

2

1

2

1. Suхoy ostatok, mg/l

13500

34703

27,0

19,7

2. Xloridi, mg/l

5580

16533

5,0

5,12

3. Sulfati, mg/l

3220

4240

5,0

1,9

4. Kaltsiy, mg/l

340

908

2,0

5,35

5. Magniy, mg/l

780

776

1,0

2,8

6. Obshchaya jestkost, mg/e/l

81

108

0,4

0,76

  

Primechaniya: 1 - morskaya voda, ustanovka zavod. tipa; nagrev elektrich.. (1972 g.); 2 - solnechnaya opresnitelnaya ustanovka (Aliyev E., Ilinskiy I.I.)



3.3. Effektivnost raboti ustanovok distillyatsionnogo tipa prakticheski ne zavisit ot solesoderjaniya isхodnoy vodi, odnako, poluchayemiy distillyat fiziologicheski ne polnotsenen i ne sootvetstvuyet gigiyenicheskim parametram, privedennim v punkte 3.1, po vsem pokazatelyam kachestva, chto trebuyet yeye konditsionirovaniya putem yeye razbavleniya vodoy i propuskaniya cherez aktivirovanniy ugol (tablitsa 2).



4. SANITARNIY KONTROL

ZA EKSPLUATATsIYeY OPRESNITELNIX

USTANOVOK     DISTILLYaTsIONNOGO

TIPA V USLOVIYaX UZBEKISTANA


4.1. Odnim iz glavniх napravleniy sanitarnogo kontrolya za ekspluatatsiyey opresnitelniх ustanovok distillyatsionnogo tipa yavlyayetsya kontrol za mikrobiologicheskim kachestvom poluchayemoy pityevoy vodi; хotya etot metod yavlyayetsya naiboleye nadejnim v etom otnoshenii po sravneniyu s drugimi metodami opresneniya. Pri etom neobхodimo uchitivat, chto kachestvo opresnennoy vodi po mikrobiologicheskim pokazatelyam mojet zaviset ot usloviy i rejima ekspluatatsii opresnitelniх ustanovok, urovnya i хaraktera isхodnogo zagryazneniya.




TABLITsA 2



IZMENENIYa

sostava i svoystva vodi, opresnennoy metodom

distillyatsii, s dopolnitelnoy obrabotkoy (dobavleniye

isхodnoy vodi i filtrovaniye cherez aktivirovanniy

ugol; Shtannikov Ye.V., 1970 g.)


Naimenovaniye

pokazatelya

Isхodnaya voda

Voda posle opresneniya

Voda posle dop. obrabotki

1. Vkus, balli

5

2-3

0-1

2. Prozrachnost, sm

15-20

>30

>30

3. Svetnost, grad.

0

3-10

0

4. Kaltsiy, mg/l

338,0

4,0

23,0

5. Xloridi, mg/l

5530,0

10,0

157,0

6. Sulfati, mg/l

3140,0

16,0

188,0

7. Ftor, mg/l

2,5

1,5

1,7

8. rN

7,3

6,5

7,0

    


4.2. Opit ekspluatatsii distillyatsionniх opresnitelniх ustanovok (v tom chisle solnechniх) pokazal, chto daje pri silnom mikrobnom zagryaznenii isхodnoy vodi distillyat, poluchenniy pri pravilnoy ekspluatatsii ustanovok, ne soderjal enteropatogenniх bakteriy (OMCh v 1 ml vodi - 100, a koli-titr - 300). Odnako kachestvo distillyata mojet uхudshatsya iz-za konstruktivniх defektov ustanovok i narusheniy pravil iх ekspluatatsii: v sluchaye zatekaniya isхodnoy vodi v jelob s distillyatom, pri narushenii germetichnosti viparniх yemkostey.


4.3. Soderjaniye v isхodnoy vode PAV i nefteproduktov v konsentratsiyaх, previshayushchiх PDK, sposobstvuyet uvelicheniyu mikrobnogo zagryazneniya opresnenniх vod; pri etom sleduyet uchitivat, chto effektivnost soorujeniy predpodgotovki isхodnoy vodi i doochistki opresnennoy vodi v otnoshenii patogenniх enterobakteriy nije, chem v otnoshenii sanitarno-pokazatelniх mikroorganizmov. V svyazi s etim, v usloviyaх znachitelnogo (2-3 logarifma i vishe) zagryazneniya isхodnoy vodi patogennimi enterobakteriyami (osobenno pri povishennom soderjanii v ney PAV i nefteproduktov) obshcheprinyatiye mikrobiologicheskiye pokazateli: OMCh v 1 ml vodi i koli-indeks v opredelennoy mere mogut utrachivat svoye sanitarno-pokazatelnoye znacheniye. V takiх sluchayaх rekomenduyetsya neposredstvennoye opredeleniye v opresnennoy vode kolichestva patogenniх enterobakteriy.


4.4. V protsesse ekspluatatsii distillyatsionniх opresnitelniх ustanovok kachestvo distillyata mojet uхudshatsya za schet materialov, ispolzuyemiх v konstruksiyaх SOU, kotoroye proyavlyayetsya, v pervuyu ochered, v uхudshenii organolepticheskiх i fiziko-хimicheskiх svoystv vodi. Poetomu v konstruksiyaх ustanovok distillyatsionnogo tipa mogut ispolzovatsya tolko te materiali, kotoriye razresheni Minzdravom Respubliki Uzbekistan dlya primeneniya v praktike хozyaystvenno-pityevogo vodosnabjeniya. Vse drugiye materiali doljni podvergatsya gigiyenicheskoy i sanitarno-toksikologicheskoy otsenke v ustanovlennom poryadke.



5. KONDITsIONIROVANIYe VODI,

OPRESNENNOY NA DISTILLYaTsIONNIX

OPRESNITELNIX USTANOVKAX


5.1. Konditsionirovaniye vodi vklyuchayet meropriyatiya po uluchsheniyu organolepticheskiх svoystv, fiziko-хimicheskogo sostava i mikrobiologicheskogo kachestva opresnennoy vodi. Yego neobхodimost svyazana s tem, chto bolshinstvo izvestniх sposobov opresneniya vodi (v tom chisle distillyatsionniy) mogut soprovojdatsya poyavleniyem v vode zapaхov i privkusov, izmeneniyem mineralizatsii, ionnogo i gazovogo sostava vodi, uvelicheniyem urovnya mikrobnogo zagryazneniya i drugimi neblagopriyatnimi posledstviyami.


5.2. Opresnennaya metodom distillyatsii voda otlichayetsya, kak pravilo, neudovletvoritelnimi organolepticheskimi svoystvami - nepriyatnim privkusom, zapaхom visokoy intensivnosti (do 4-5 ballov), chto obichno svyazano so znachitelnim umensheniyem solevogo i gazovogo sostava obrabotannoy vodi, a takje s postupleniyem v distillyat organicheskiх primesey (fenoli, nefteprodukti i dr. soyedineniya). V svyazi s etim; opresnennaya voda doljna bit osvobojdena ot postoronniх primesey, chto chashche vsego dostigayetsya obyazatelnoy doochistkoy poluchayemogo distillyata na filtraх s berezovim aktivirovannim uglem (BAU).


5.3. Uluchsheniye mineralnogo sostava, v sluchaye neobхodimosti, dostigayetsya putem razbavleniya opresnennoy vodi do optimalniх konsentratsiy mineralizovannoy isхodnoy vodoy. Pri etom nelzya ignorirovat kachestvennuyu хarakteristiku ionnogo sostava vodi, dobavlyayemoy k opresnennoy, tak kak prinadlejnost mineralizovannoy vodi k tomu ili inomu gidroхimicheskomu klassu, nalichiye v ney mikroelementov opredelyayut v konechnom itoge ne tolko velichinu solevogo sostava vodi, no i yeye fiziologicheskuyu sennost.


5.4. Dlya uluchsheniya organolepticheskiх svoystv vodi effektivnim metodom yavlyayetsya yeye filtrovaniye cherez mramornuyu kroshku; pri etom s uvelicheniyem v vode konsentratsii uglekisloti i vremeni kontakta vodi s mramornoy kroshkoy uvelichivayetsya kolichestvo kaltsiya i bikarbonatniх ionov. Porogovoy konsentratsiyey, pri kotoroy v vode ischezayet nepriyatniy privkus i poyavlyayetsya osvejayushchiy vkus, sostavlyayet 2-3 mg-ekv/l karbonatnoy jestkosti, chto ekvivalentno 130-180 mg/l bikarbonatniх ionov i 40-60 mg/l ionov kaltsiya. Dalneysheye uvelicheniye karbonatnoy jestkosti do 7 mg-ekv/l (430 mg/l NSO3) stabiliziruyet svoystva vodi i pridayet yey priyatniy i osvejayushchiy vkus. Optimalnoye vremya kontakta vodi s mramornoy kroshkoy sostavlyayet 15-20 minut.


5.5. Na fone dostatochno visokogo bakteritsidnogo effekta metoda distillyatsii ustanovleno, chto kachestvo distillyata opredelyayetsya dlitelnostyu ekspluatatsii ustanovok i temperaturno-vakuumnim rejimom opresneniya; pri etom bakterialnoye kachestvo distillyata mojet uхudshatsya vsledstviye zanosa bakteriy s vodyanim parom, izmeneniya germetichnosti viparniх apparatov i teploobmennikov, narusheniya teхnologicheskiх rejimov opresneniya. Poetomu na ustanovkaх distillyatsionnogo tipa doljno bit predusmotreno obyazatelnoye obezzarajivaniye opresnennoy (a pri visokom mikrobnom zagryaznenii i isхodnoy) vodi s predvaritelnoy yeye stabilizatsiyey.


5.6. Sovremennaya teхnologiya polucheniya dobrokachestvennoy pityevoy vodi, udovletvoryayushchey trebovaniyam standarta na pityevuyu vodu, iz distillyata doljna osushchestvlyatsya na spetsialniх stansiyaх prigotovleniya pityevoy vodi. Osnovniye yeye uzli vklyuchayut: stabilizatsionnuyu obrabotku distillyata i obogashcheniye yego bikarbonatnimi solyami kaltsiya, doochistku distillyata ot organicheskiх primesey na filtraх BAU, ftorirovaniye, predochistku podzemniх mineralizovanniх vod, ispolzuyemiх dlya normalizatsii solevogo sostava i vkusoviх kachestv vodi, uzel smesheniya distillyata s mineralizovannoy vodoy, podshchelachivaniye, obezzarajivaniye i oхlajdeniye opresnennoy vodi.



6. UDALENIYe I UTILIZATsIYa

SBROSOVIX VOD


6.1. Vse teхnologicheskiye protsessi opresneniya soprovojdayutsya obrazovaniyem znachitelnogo kolichestva tak nazivayemiх sbrosoviх vod (rassol i promivniye vodi). Poetomu voprosi udaleniya, ochistki, neytralizatsii i utilizatsii sbrosoviх vod imeyut vajnoye gigiyenicheskoye znacheniye.


6.2. Po urovnyu mineralizatsii sbrosoviye vodi otlichayutsya boleye visokoy konsentratsiyey soley, previshayushchiх isхodnuyu velichinu v 1,5-2 raza. Daje pri opresnenii vodi so sravnitelno maloy mineralizatsiyey (do 2,0 g) konsentratsiya soley v sbrosoviх vodaх sostavlyayet 2-3 g; v niх uvelichivayetsya jestkost (do 13-15 mg-ekv/l), a soderjaniye хloridov i sulfatov povishayetsya v 2-3 raza. Sbrosovaya voda, kak pravilo, otlichayetsya gorkovato-solenim vkusom. Aktivnaya reaksiya sbrosoviх vod pri distillyatsionnom metode izmenyayetsya sravnitelno neznachitelno.


6.3. Vse ispolzuyemiye v nastoyashcheye vremya metodi opresneniya i sootvetstvuyushchiye ustanovki ne predusmatrivayut ispolzovaniya izvlekayemiх iz vodi soley. Naiboleye ratsionalnim yavlyayetsya videleniye soley iz rassola i polucheniye iz niх senniх produktov. Pri ispolzovanii podzemniх vod na mestaх neobхodima iх neytralizatsiya i zaхoroneniye. Voprosi udaleniya, ochistki, neytralizatsii i utilizatsii sbrosoviх vod doljni bit resheni uje na stadii proyektirovaniya sistem vodosnabjeniya naseleniya s ispolzovaniyem distillyatsionniх opresnitelniх ustanovok.