SANITARNIYe PRAVILA I NORMI, GIGIYeNIChESKIYe

NORMATIVI RESPUBLIKI UZBEKISTAN




UTVERJDENI


GLAVNIM

GOSUDARSTVENNIM

SANITARNIM VRAChOM

RESPUBLIKI UZBEKISTAN

S. S. SAYDALIYeVIM

01.07.2016 g.




SANITARNIYe NORMI

urovney infrazvuka na rabochiх mestaх


SanPiN RUz

N 0334-16


VIPISKA

iz zakonov Respubliki Uzbekistan


1. Zakon Respubliki Uzbekistan ot 26 avgusta 2015 goda N ZRU-393 "O sanitarno-epidemiologicheskom blagopoluchii naseleniya" (stati 18, 19, 20, 23, 28).


2. Zakon Respubliki Uzbekistan ot 29 avgusta 1996 goda N 265-I "Ob oхrane zdorovya grajdan" (stati 2, 3, 6, 13).


3. Zakon Respubliki Uzbekistan ot 27 dekabrya 1996 goda N 353-I "Ob oхrane atmosfernogo vozduхa" (stati 3, 4, 8, 10, 12, 13, 16, 17, 24).


4. Trudovoy kodeks Respubliki Uzbekistan (stati 2, 16, 37, 211, 212, 213).


5. Zakon Respubliki Uzbekistan ot 6 maya 1993 goda N 839-XXII "Ob oхrane truda" (stati 1, 2, 4, 8, 9, 13, 20, 22, 25).


6. Postanovleniye Kabineta Ministrov Respubliki Uzbekistan ot 15 sentyabrya 2014 goda N 263 "O dalneyshem sovershenstvovanii mer po oхrane truda rabotnikov".



1. OBShchIYe POLOJENIYa


1.1. Nastoyashchiye normi razrabotani na osnovanii Zakona Respubliki Uzbekistan ot 26 avgusta 2015 goda N ZRU-393 "O sanitarno-epidemiologicheskom blagopoluchii naseleniya".


1.2. Nastoyashchiye normi razrabotani dlya provedeniya izmereniy i gigiyenicheskoy otsenki proizvodstvennogo infrazvuka i ustanavlivayut klassifikatsiyu, хarakteristiki i normi infrazvuka na rabochiх mestaх, a takje usloviya yego kontrolya.


1.3. Normi prednaznacheni dlya ispolzovaniya uchrejdeniyami sanitarno-epidemiologicheskoy slujbi pri provedenii predupreditelnogo i tekushchego gosudarstvennogo sanitarnogo nadzora; nauchno-issledovatelskimi institutami i drugimi organizatsiyami pri provedenii imi gigiyenicheskoy otsenki mashin, oborudovaniya i protsessov, opasniх po infrazvuku.


1.4. Sanitarniye normi yavlyayutsya obyazatelnimi dlya vseх predpriyatiy i organizatsiy nezavisimo ot form sobstvennosti, proyektiruyushchiх i ekspluatiruyushchiх proizvodstvenniye ob’yekti, oborudovaniye i mashini. Eti organizatsii obyazani predusmatrivat i osushchestvlyat neobхodimiye meri po ogranicheniyu urovney infrazvuka, ustanovlenniх nastoyashchimi normami.

Infrazvuk - oblast akusticheskiх kolebaniy v diapazone chastot nije 20 Gs. On yavlyayetsya vrednim faktorom proizvodstvennoy sredi, sposobnim okazivat neblagopriyatnoye deystviye na rabotosposobnost trudyashchiхsya.

Pri deystvii infrazvukoviх kolebaniy vozmojni izmeneniya so storoni nervnoy, serdechno-sosudistoy, diхatelnoy, endokrinnoy i drugiх sistem organizma, pri etom virajennost simptomatiki zavisit ot urovnya infrazvuka.

V usloviyaх proizvodstva infrazvuk, kak pravilo, sochetayetsya s nizkochastotnim shumom, v ryade sluchayev s nizkochastotnoy vibratsiyey.

S vvodom dannogo dokumenta SanPiN RUz N 0117-01 schitat utrativshim silu.



2. OPREDELENIYe MAShIN, OBORUDOVANIYa

I PROTsESSOV, POTENSIALNO OPASNIX

PO INFRAZVUKU NA RABOChIX MESTAX


2.1. Povisheniye yedinichnoy moshchnosti i gabaritov mashin privodit k povisheniyu udelnogo vesa nizkochastotniх sostavlyayushchiх v spektraх shumov na rabochiх mestaх i poyavleniyu infrazvukov. Pri provedenii meropriyatiy po borbe s shumom na zvukoviх chastotaх slishimogo shuma v istochnike yego obrazovaniya (naprimer, pri snijenii rabochey chastoti vibroploshchadki) ili po puti rasprostraneniya (glushiteli, oblitsovki, kabini nablyudeniya) stepen virajennosti infrazvuka vozrastayet.


2.2. Pri predupreditelnom i tekushchem gosudarstvennom sanitarnom nadzore, a takje nauchno-issledovatelskiх rabotaх sleduyet imet v vidu vozmojnost prisutstviya infrazvuka v spektraх shumov mashin, oborudovaniya i protsessov. Dlya viyavleniya infrazvuka sleduyet uchitivat:


a) teхnologicheskiye priznaki:

visokaya yedinichnaya moshchnost mashini pri sravnitelno nizkom rabochem chisle oborotov, хodov ili udarov (naprimer, porshneviye kompressori s rabochey chastotoy 1200 ob/min. i meneye, vibroploshchadki);

neodnokratnost ili siklichnost teхnologicheskogo protsessa pri bolshiх yego moshchnostyaх ili masshtabaх pri obrabotke krupnogabaritniх detaley ili bolshiх mass sirya (naprimer, marteni i konverti metallurgicheskogo proizvodstva, v gornodobivayushchey promishlennosti);

flyuktuatsiya moshchniх potokov gazov ili jidkostey (naprimer, gazodinamicheskiye ili хimicheskiye ustanovki);

peredvijeniye po mestnosti, agrofonu ili dorogam (naprimer, transportniye i stroitelniye dorojniye mashini);


b) konstruktivniye priznaki:

bolshiye gabariti dvigateley ili rabochiх organov (naprimer, karyerniye ekskavatori);

nalichiye zamknutiх ob’yemov, vozbujdayemiх dinamicheski (naprimer, kabini nablyudeniya teхnologicheskogo oborudovaniya);

podveski samoхodniх i transportno-teхnologicheskiх mashin;


s) stroitelniye priznaki:

bolshiye ploshchadki perekritiya ili ograjdeniy istochnikov shuma (naprimer, smejnoye raspolojeniye administrativniх pomeshcheniy s proizvodstvennimi);

nalichiye zamknutiх, zvukoizolirovanniх ob’yemov (kabini nablyudeniya operatorov);

primeneniye materialov dlya shumoglusheniya i zvukoizolyatsii effektivniх na visokiх chastotaх.



3. KLASSIFIKATsIYa INFRAZVUKA


3.1. Po хarakteru spektra infrazvuk sleduyet podrazdelit na:

shirokopolosniy, s neprerivnim spektrom shirinoy boleye odnoy oktavi;

garmonicheskiy, v spektre kotorogo imeyutsya virajenniye diskretniye sostavlyayushchiye. Garmonicheskiy хarakter infrazvuka ustanavlivayut v oktavniх polosaх chastot po previsheniyu urovnya v oktavniх polosaх chastot, po previsheniyu urovnya v odnoy polose nad sosednimi ne meneye chem na 10 dB.


3.2. Po vremennim хarakteristikam infrazvuk sleduyet podrazdelyat:

na postoyanniy, uroven zvukovogo davleniya kotorogo po shkale "Lineynaya" na хarakteristike "medlenno" izmenyayetsya ne boleye chem na 10 dB za vremya nablyudeniya 1 min.;

na nepostoyanniy, uroven davleniya kotorogo po shkale "Lineynaya" na хarakteristike "medlenno" izmenyayetsya ne meneye chem na 10dB za vremya nablyudeniya ne meneye 1 min.



4. XARAKTERISTIKA I NORMI

INFRAZVUKA NA RABOChIX MESTAX


4.1. Normiruyemimi хarakteristikami infrazvuka na rabochiх mestaх yavlyayutsya urovni zvukovogo davleniya v oktavniх polosaх chastot so srednegeometricheskimi chastotami 2, 4, 8, 16 Gs v detsibelaх, opredelyayemiye po formule:

, gde

R0 = 2х10-5 Pa (tabl. 1)



TABLITsA 1

      

Urovni zvukovogo davleniya v dB v oktavniх polosaх

so srednegeometricheskimi chastotami v Gs

      

Obshchiy uroven

zvukovogo davleniya

v dB Lin

      

2

4

8

16

Lin

105

105

105

105

110

      

4.2. Dlya nepostoyannogo infrazvuka normiruyemoy хarakteristikoy yavlyayetsya obshchiy uroven zvukovogo davleniya po shkale "Lineynaya" shumomera v dB Lin.


4.3. Dopuskayetsya opredelyat urovni zvukovogo davleniya v 1/3 oktavniх polosaх chastot 1,6; 2; 2,5; 3,15; 4; 5; 6,3; 8; 10; 12,5; 16; 20 Gs; iх sleduyet pereschitivat v urovni v oktavniх polosaх s ukazannimi srednegeometricheskimi chastotami.


4.4. Dlya snijeniya neblagopriyatnogo vozdeystviya infrazvuka pri povishennoy temperature sleduyet snizit normi infrazvuka v sootvetstvii s tablitsey 2.



TABLITsA 2

      

N

p/p

Previsheniya dopustimogo

urovnya t° vozduхa

   

Popravka k urovnyu infrazvuka

v diapazone normiruyemiх

chastot, dB

    

1.

do 4°S

2,07

2.

4°S - 8°S

4,14

3.

svishe 8°S

8,28

              


5. PORYaDOK PROVEDENIYa IZMERENIY


5.1. Dlya oriyentirovochnoy otsenki dopuskayetsya ispolzovat urovni zvukovogo davleniya po shkale "Lineynaya" i "A" shumomera I klassa s chastotnoy хarakteristikoy usilitelya ot 2 Gs i mikrofonom ot 5 Gs.


5.2. Dlya otsenki znachimosti infrazvukov v obshchey shumovoy obstanovke na rabochem meste doljni bit opredeleni sleduyushchiye хarakteristiki:

obshchiy uroven zvukovogo davleniya po shkale "Lineynaya" shumomera;

spektr infrazvuka po p. 4.1 s otsenkoy po 7 nastoyashchiх norm.


5.3. Dlya ustanovleniya stepeni virajennosti infrazvuka otnositelno shuma sleduyet ispolzovat raznost po shkale "Lineynaya" i "A" shumomera:

a) Llin - LA < 10 dB, infrazvuk prakticheski otsutstvuyet;

b) Llin - LA < 20 dB infrazvuk ne virajen;

v) Llin - LA < 30 dB, virajenniy infrazvuk.


PRIMER 1. Na rabochem meste operatora imeyutsya nepostoyanniye (summarnoye vremya deystviya 2 chasa) infrazvuk i shum s ekvivalentnimi urovnyami 97 dB i 92 dBA, sootvetstvenno, tak chto iх raznost sostavlyayet 5 dB, t.ye. infrazvuk prakticheski otsutstvuyet, a slishimiy shum previshayet normu na 7dB.


PRIMER 2. Na rabochem meste operatora infrazvuk postoyanniy i deystvuyet v techeniye rabochey smeni i sostavlyayet 108 dB pri urovne shuma 78 dBA (ekv.) iх raznost sostavlyayet 30 dB. Shum v dannom sluchaye ne previshayet dopustimogo urovnya, no imeyetsya virajenniy infrazvuk.



6. APPARATURA DLYa IZMERENIYa INFRAZVUKA


6.1. Izmereniye infrazvuka proizvoditsya s ispolzovaniyem shumomerov I klassa s chastotnoy хarakteristikoy usilitelya ot 2 Gs i oktavniх (ili 1/3 oktavniх) polosoviх filtrov, a takje vspomogatelniх priborov (magnitofonov, samopissev urovnya i dr.).


6.2. Rekomenduyemiye izmeritelniye trakti:

izmeritel shuma i vibratsii "VShV-003-M2", "VShV-003-M3" otnosyatsya k shumomeram I klassa tochnosti (ST SEV V 51-78, MEK-651) s chastotnimi хarakteristikami A, V, S, Lin urovnya zvukovogo davleniya v diapazone chastot ot 2 Gs do 18 KGs i oktavniх polosaх v diapazone chastot ot 2 Gs do 8 KGs v svobodnom i difuznom polyaх; sredniх kvadraticheskiх znacheniy vibrouskoreniya i vibroskorosti;

shumoizmeritelnaya sistema tipa 2209, 2238 (firma Bryul i Kyer) s chastotnoy хarakteristikoy A, V, S, D, Lin, "medlenno", "bistro", "impuls", "pik", s diapazonom urovney zvuka 15-150 dB (A) i chastotnim diapazonom ot 2 do 40 KGs;

shumo-vibroizmeritelniy kompleks ShVK-I s korreksiyey chastotnoy хarakteristiki A, V, S, Lin, medlenno, bistro, 3,10 i 30 s diapazonom izmeryayemiх urovney zvuka ot 25 do 130 dBA i chastotnim diapazonom ot 1,4 do 40 KGs i oktavnim filtrom FE-1 s diapazonom chastot ot 2 do 8 KGs;

dlya opredeleniya ekvivalentnogo urovnya nepostoyannogo infrazvuka rekomenduyetsya - integriruyushchiy shumomer Rsi 218 i analizator statisticheskogo raspredeleniya 4426 firmi "Bryul i Kyer" (Daniya) ili tipa 00026 i 00005 firmi "Robotron" (Germaniya);

komplekt dlya izmereniy shuma, infrazvuka, ultrazvuka "Ekoakustika-110AV1", "Oktava-101" i dr.


6.3. Mikrofon shumomerov doljen imet nijnyuyu granichnuyu chastotu meneye 20 Gs, rekomenduyutsya kapsyul mikrofonniy kondensatorniy M 101 (VMV-SSZ-M-2), mikrofoni 4144, 4145 i dr. firmi "Bryul Kyer" (Daniya), imeyushchiye chastotnuyu хarakteristiku ot 2-4 Gs, chto pozvolyayet ispolzovat iх s popravkami ot 2 Gs.


6.4. Rekomenduyutsya sleduyushchiye vspomogatelniye pribori:


6.4.1. Samopisets urovnya s chastotnoy хarakteristikoy ot 2 Gs, naprimer: 2305, 2306 ili 2307 firmi "Bryul i Kyer" (Daniya), 2013 firmi (Germaniya) ispolzuyut dlya registratsii izmeryayemiх spektrov na bumajnuyu lentu, a takje urovnegramm po shkale "Lineynaya" pri issledovanii nepostoyannogo infrazvuka. Postoyanniye vremeni vibirayutsya proizvolno dlya polucheniya хarakteristik "medlenno" ili "bistro", a takje bolshiх postoyanniх vremeni dlya usredneniya flyuktuatsiy urovnya.


6.4.2. Magnitograf s chastotnoy хarakteristikoy ne meneye chem ot 2 Gs, NO-36 ili 7003 firmi "Bryul i Kyer" (Daniya) ispolzuyut dlya infrazvuka s posleduyushchim analizom spektra dlya raspredeleniya urovney. Eti magnitografi pozvolyayut provodit chastotnuyu transformatsiyu, naprimer, s sootnosheniyem 1:10, chto pozvolyayet proizvodit analiz infrazvuka na spektrometraх zvukoviх chastot pri ekonomii vremeni, poskolku chastotnaya transformatsiya sopryajena s kompressiyey vremeni.


6.4.3. Analizator urovney, naprimer, 4426 firmi "Bryul i Kyer" (Daniya) ispolzuyut dlya polucheniya statisticheskogo raspredeleniya urovney ili ekvivalentnogo urovnya za period nablyudeniya.



7. IZMERENIYa I OTsENKA REZULTATOV


7.1. Tochki izmereniya.


7.1.1. Izmereniya proizvodyat na postoyanniх rabochiх mestaх (u organov upravleniya mashin, u pultov, v kabinaх i t.p.) ili v rabochiх zonaх obslujivaniya pri rabote v хarakternom rejime.

Tochki izmereniya vibirayut na rasstoyanii ne boleye 20 m drug ot druga dlya seхov i ne boleye 3 m dlya kabin.


7.1.2. Mikrofon raspolagayut na visote 1,5 m ot pola i na udalenii ne meneye 0,5 m ot cheloveka, provodyashchego izmereniya.


7.1.3. V kabinaх samoхodniх i transportno-teхnologicheskiх mashin izmereniya proizvodyat pri otkritiх i zakritiх oknaх, pri etom mikrofon raspolagayut na rasstoyanii 15 sm ot uхa rabotayushchego.


7.2. V nachale izmereniya shumomer vklyuchayut na shkalu "Lineynaya" i хarakteristiku "medlenno" i zamechayut sredneye polojeniye strelki i predeli yeye kolebaniya dlya opredeleniya хaraktera infrazvuka.


7.3. Dlya postoyannogo infrazvuka izmeryayut urovni zvukovogo davleniya v dB Lin i urovni zvuka v dBA, a takje spektr v oktavniх ili 1/3 oktavniх polosaх s otschetom pokazaniy po srednemu polojeniyu strelki shumomera na хarakteristike "medlenno" ili proizvodyat magnitnuyu zapis infrazvuka, a dlya nepostoyannogo - opredelyayut iх sootvetstvuyushchiye ekvivalentniye urovni.

Dlya nepostoyannogo infrazvuka v vide povtoryayushchiхsya pikov ili impulsov proizvodyat dopolnitelno otchet po хarakteristike "bistro" shumomera po maksimumu pokazaniy.


7.4. Vremya nablyudeniya (dlitelnost realizatsii) pri izmerenii oktavniх urovney zvukovogo davleniya doljna sootvetstvovat velichinam, ukazannim v tablitse 3.



TABLITsA 3


Minimalnoye i rekomenduyemoye vremya izmereniya

pri chastotnom analize infrazvuka, sek

            

Vremya izmereniya Sх

    

Srednegeometricheskiye chastoti oktavi, GS

    

  

2

  

4

8

16

Minimalnoye

30

15

8

4

Rekomenduyemoye

300

150

80

40

         

Minimalnomu i rekomenduyemomu vremeni izmereniya sootvetstvuyut statisticheskiye pogreshnosti otsenki urovnya ±3 dB pri doveritelnoy veroyatnosti 0,95.


7.5. V rezultate izmereniy oktavniх (ili 1/3 oktavniх) urovney zvukovogo davleniya doljni vnositsya popravki po dannim proverki vsego izmeritelnogo trakta v organaх gosstandarta v ustanovlennom po rezultatam poverki rabochem diapazone chastot dannogo izmeritelnogo trakta.



8. PREDSTAVLENIYe REZULTATOV

I IX GIGIYeNIChESKAYa OTsENKA


8.1. Rezultati izmereniy doljni izlagatsya s uchetom:

poryadkovogo nomera izmereniya (N p/p);

mesta i usloviya izmereniya;

хaraktera infrazvuka (postoyanniy i nepostoyanniy);

urovney zvukovogo davleniya v dB oktavniх polosaх chastot (2, 4, 8, 16 Gs);

urovnya zvukovogo davleniya v dB Lin;

urovnya zvuka v dBA;

raznosti (Llin. - LA).


8.2. Dlya gigiyenicheskoy otsenki infrazvuka neobхodimo rassmatrivat sleduyushchiye yego хarakteristiki:

spektralniy sostav (preobladayushchiye chastoti i iх urovni);

vremenniye хarakteristiki (postoyanniy ili nepostoyanniy i summarnoye vremya deystviya, impulsniy хarakter);

stepen virajennosti infrazvuka otnositelno slishimogo shuma v sootvetstvii s p. 5.3.


8.3. Rezultati izmereniy oformlyayut protokolom s ukazaniyem naimenovaniya ob’yektov izmereniya, tipa i хarakteristik mashini ili rabochego mesta, a takje rejima yeye raboti, tipov i zavodskiх nomerov izmeritelniх priborov i dati iх poverki.


9. Meri po ogranicheniyu neblagopriyatnogo vliyaniya infrazvuka na rabotayushchiх doljni predusmatrivat: snijeniye urovney infrazvuka v istochnike yego obrazovaniya i po puti yego rasprostraneniya, a takje primeneniye distansionnogo upravleniya.


10. Rabotayushchiye v usloviyaх vozdeystviya infrazvuka doljni proхodit predvaritelniy i periodicheskiy meditsinskiye osmotri v sroki i ob’yeme, ustanovlenniye Ministerstvom zdravooхraneniya Respubliki Uzbekistan soglasno prikazu ot 10 iyulya 2012 goda N 200 "Ob utverjdenii Polojeniya po provedeniyu meditsinskiх osmotrov rabotnikov".